OPERATION
A/C and Heater
Explanations • Corrective action
Fault Code Read From the Heater
Malfunction description
Blower motor does not rotate or short circuit after negative Please note! Provide compliance with the test voltage Part is destroyed if the voltage value is exceeded. Make sure that the power supply has adequate short circuit resistance (20 A minimum). Blower motor, output (+) - short circuit after UB (battery voltage)
21
Call the authorized service
4
22 2F 30 31 32 33
Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service
Metering pump - short-circuit or overload
Metering pump - interruption
Metering pump output (+) - short circuit after UB (battery voltage) Too many failed operation attempts (operation locked)
Flame detected during operation
No flame detected during operation cycle. • Check the exhaust and combustion air system. * Check the fuel supply / fuel amount Call the authorized service if the problem is not solved Heater ignited during power stage (flame detected) and flame interruption signal issued. • Check the exhaust and combustion air system. * Check the fuel supply / fuel amount Call the authorized service if the problem is not solved Heater ignited during power stage (flame detected) and flame interruption signal issued. • Check the exhaust and combustion air system. * Check the fuel supply / fuel amount Call the authorized service if the problem is not solved Heater ignited during power stage (flame detected) and flame interruption signal issued. • Check the exhaust and combustion air system. * Check the fuel supply / fuel amount Call the authorized service if the problem is not solved
34
Safety time exceeded
35
Flame interruption during “POWER” control
36
Flame interruption during “HIGH” control stage
37
Flame interruption during “MEDIUM” control stage
- 97 -