Technichal data Heater type

Airtronic M

Heater

Airtronic D3 / Airtronic D4 / Airtronic D4 Plus

Version

D3 / D4 / D4 Plus

Heating medium

Air

Control of the heat flow

Stage

Power 3000 4000 4000

Large

Medium Small

Off

Heater air flow rate without counterpressure (kg/h)

D3 D4

2200 3000 3000

1600 2000 2000

900 –

900

D4 Plus

900 –

Heater air flow rate without counterpressure (kg/h)

150 D3 with hood Ø 90 mm D4 with hood Ø 90 mm 185 D4 Plus with hood Ø 75 mm 185

120 150 140

90 110

60 24 60 22

100 0,24 0,25 0,25

55

– – – – 5 5 5

Fuel consumption (l/h)

D3 0,38 D4 0,51

0,28 0,38 0,38

0,11 0,11 0,11

D4 Plus

0,51

Elektr. power consumption (watt) iin operationt (12 and 24 volt)

D3

24

16 24 30

10 13 16

7 7 7

D4 40

D4 Plus

55

at start (12 and 24 volt)