F-MAX-USER MANUAL-FULL BOOK-ENGLISH
AUXILIARY HEATER
Airtronic/Airtronic M
Technichal data Heater type
Airtronic M
Heater
Airtronic D3 / Airtronic D4 / Airtronic D4 Plus
Version
D3 / D4 / D4 Plus
Heating medium
Air
Control of the heat flow
Stage
Power 3000 4000 4000
Large
Medium Small
Off
Heater air flow rate without counterpressure (kg/h)
D3 D4
2200 3000 3000
1600 2000 2000
900 –
–
900
D4 Plus
900 –
Heater air flow rate without counterpressure (kg/h)
150 D3 with hood Ø 90 mm D4 with hood Ø 90 mm 185 D4 Plus with hood Ø 75 mm 185
120 150 140
90 110
60 24 60 22
100 0,24 0,25 0,25
55
– – – – 5 5 5
Fuel consumption (l/h)
D3 0,38 D4 0,51
0,28 0,38 0,38
0,11 0,11 0,11
D4 Plus
0,51
Elektr. power consumption (watt) iin operationt (12 and 24 volt)
D3
24
16 24 30
10 13 16
7 7 7
D4 40
D4 Plus
55
at start (12 and 24 volt)
≤100
- 249 -