F-MAX-USER MANUAL-FULL BOOK-ENGLISH

AUXILIARY HEATER

Hydronic M-II

• Minimum water flow rate of the heater

500 l/h

Commercially available diesel (DIN EN 590) FAME – for diesel engines according to DIN EN 14 214

Fuel – see also “Fuel quality diesel heaters” page 27

Tolarable ambient temperature

Operation

Not running

Diesel FAME Diesel FAME

–40 °C to +80 °C –8 °C to +80 °C –40 °C to +50 °C –8 °C to +50 °C

–40 °C to +85 °C –40 °C to +85 °C –40 °C to +85 °C –40 °C to +85 °C

Heater / Control box

Dosing pump

Interference suppression class

interference suppression class 5 to DIN EN 55 025

Weight with controller and water pump, without dosing pump

approx. 6.2 kg

CAUTION! Safety instructions for technical data! Failure to comply with the technical data can result in malfunctions.

Please note! Provided no limit values are given, the technical data listed is subject to the tolerances usually applicable to heaters of ±10% for nominal voltage, ambient tempera- ture 20 °C and reference altitude Esslingen.

- 297 -