AUXILIARY HEATER
Hydronic M-II
Technichal data Heater type
Hydronic M-II Hydronic M12
Heater
Version
D 12 W
Heating medium
Mixture of water and coolant (max. 50 %water, 50 % coolant)
Control of the heat flow
Power
Large Medium 1 Medium 2 Medium 3 Small
Heat flow (watt)
12000
1500
9500
5000
5000
1200
0.18
Fuel consumption (l/h) Electrical power (watt)
1.5
1.2
0.65
0.40
0.15
34
in operation 132
60
86
46
34
at start – after 25 Sek. in the control phase “OFF”
120
32
Rated voltage
12 Volt
24 Volt
Operating range • Lower voltage limit: An undervoltage protection in the controller switches the heater off on reaching the voltage limit. • Upper voltage limit: An overvoltage protection in the controller switches the heater off on reaching the voltage limit.
10 Volt
20 Volt
15 Volt
30 Volt
Tolerable operating pressure
up to 2 bar overpressure
Flow rate of the water pump at 0.14 bar
1400 l/h