AUXILIARY HEATER
Hydronic M-II
Possible installation positions The heater should preferably be installed in the normal position, horizontal with the exhaust connection down to the bottom. Depending on the installation conditions, the heater can also be mounted in the permitted swivel range, see diagram. When the heater is operating, the shown normal or maximum installation positions can be varied briefly by up to +15° in all directions. Such deviations caused by the inclined position of the vehicle do not impair the heater functions in any way.
Normal position with permitted swivel range • Swivel range from the normal position swivelled up to max. 85° downward – the heater‘s water outlet socket is horizontal. The water pump‘s water inlet socket must face downward. • Swivel range from the normal position swivelled up to max. 90° to the left about the longitudinal axis – the water outlet socket is at the top of the heater and faces the left.