S05_G_ASE_LHD_REEV_English_15AUGUST
Emergency rescue
High voltage discharge method
If you need to cut off the high-voltage system urgently, you must first disconnect the high voltage circuit connection and then disconnect the negative terminal battery. Disconnect the high-voltage circuit by unplugging the high-voltage interlock circuit connector, which is located next to the cabin fuse box.
The method of cutting off the high voltage system is as follows:
1. Open the hood;
2. Find the high-voltage interlock circuit connector Elocated above wheel wrap near the driver's side and below the engine compartment fuse box ;
3. Pull out the locking spring on the connector housing, press the spring and unplug the connector to disconnect the high-voltage circuit of the vehicle;
4. Open the trunk, disconnect the negative battery cable and insulate it.
DANGER
• Do not manually shut off the high-voltage system except in emergency situations.
• If you have other related questions during the operation, please contact the authorized dealer of Changan Automobile.
227