OPERATION
A/C and Heater
Explanations • Corrective action
Fault Code Read From the Heater
Malfunction description
Heater ignited during power stage (flame detected) and flame interruption signal issued. • Check the fuel amount, the blower speed, the fuel supply and the exhaust and the combustion air system. Call the authorized service if the problem is not solved Heater ignited during power stage (flame detected) and flame interruption signal issued. • Check the fuel amount, the blower speed, the fuel supply and the exhaust and the combustion air system. Call the authorized service if the problem is not solved
Flame interruption:
39
"Medium 3" control stage (D 12 W)
4
Flame interruption:
3A
"LOW" control stage
3B 3C 3D 40 41 47 48 4A 5A 5B 5C 5D
Water temperature increasing too quickly
Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service Call the authorized service
Temperature sensor interruption Temperature sensor short circuit Flame detector interruption Flame detector short circuit Overheating detector interruption Overheating detector short circuit
Sensing equipment faulty on the overheating detector, operation locked
External reset Internal reset
ROM error
RAM error, at least one RAM cell does not operate
EEPROM error, operation data, diagnostic parameters or checksum error in the setting values field
5E
Call the authorized service
5F
Invalid data record checksum error Internal temperature sensor faulty
Call the authorized service Call the authorized service
60
/ ECU too hot
61
Internal device error
Call the authorized service Call the authorized service Call the authorized service
62 63
Main relay faulty
Too many resets, operation locked